Z Series DC Motor
Energy: 55kw- 1600KW
Voltage: regular 400V, 440V, 660V
Pace: rated velocity reference
Defense Degree: IP23/IP44
Insulation Course: F
Duty: S1
Deal: export picket package deal
Payment: thirty% in progress, balance by T/T or L/C at sight
Z355-4A, 375KW, 550V, 1220r/min, IC06, IP23/IP44, F Insulation
CZPT
1. The techniques and safety diploma of the motor
a) The approach of cooling of the motor is individually-cooled, in accordance to GB/T1993 “Strategy of cooling of rotating electrical machinery”, there are IC06, IC17, IC37, IC86W. CZPT entrance of cooling air is at the stop of the principal transmission(not the commutator facet). The security course of the motor can be divided into IP23 and IP44 in accordance to the GB/T4942.one and IEC34-5. If the person needs other technique of cooling and defend class, it can be negotiated.
b) the relation in between the technique of cooling and the protection diploma of the motor pls see
Desk one.
c) the cooling method, wind strain, cooling drinking water flux, motor power see: Desk 2.
|
Body |
Created-on blower |
air-to-h2o heat exchanger |
|||||
|
cooling wind |
Wind pressure (whisht force) |
motor electricity |
excess weight |
Cooling water flux |
motor power |
bodyweight |
|
|
m³/hr |
Pa |
KW |
KG |
m³/hr |
KW |
KG |
|
|
H500 |
10000 |
1900 |
seven.five |
three hundred |
19 |
11 |
900 |
|
H560 |
16500 |
2250 |
15. |
400 |
22 |
eighteen.5 |
1100 |
|
H710 |
23500 |
2400 |
18.five |
600 |
forty |
two*eleven |
1600 |
two. The installation and the kind of motor in accordance to the GB/T997 “the composition and installation kind of rotating electrical equipment”, have IM1001(Horizontal bottom put in, column biaxial) and IM1002 (Horizontal base set up, column biaxial). If the consumer needs other varieties of installation composition, it need to be negotiated.
three. The placement of terminal box on normal motor is on the proper facet when observing from the principal generate finish. It can also be set up on the left aspect, but it must be written in the purchase contract.
4. The motor using rolling bearing, nonstop adding oil structure.
5. The motor can be installed the following add-ons at the user’s option.
a) temperature detector part can be place into stator winding and bearing room of 2 side, and hook up the outlet wire to the terminal box.
b) The non-push social gathering of the device can equipped with tacho-generator, centrifugal starting up swap, coder and other individuals which construct up the velocity meter defending system.
c) Heater for stopping condensation can be put in in the motor, but it need to be prepared in the other contact
six. The air-to water heat exchanger is generally mounted on the leading of the motor. If the consumer needs to be mounted on the aspect of the motor, the person should place CZPT it when purchasing and settle the assistant upholder by the consumer himself.
seven. The cooler outfitted with wind pressure swap, temperature controller, heater for avoiding condensation and pther shield unit.
Order notice
one. The motor type, power, voltage, running speed, excitation type, cooling type, number of output draft, position of outlet box, etc. Must be written when ordering.
two. Pls give clear indication of the accessory’s type, specification and number installed on the motor when ordering.
three. If the environment of using is special, humid torrid zone type motor is needed pls write “H” after the original type.
4. If you have some special requirement of the specification and technical requirement which is not listed in the booklet, pls contact us.
Packaging & Delivery
Testing Equipment